Deep learning CT reconstruction improves liver metastases detection
Insights into Imaging volume 15, Article number: 167 (2024)
Abstract
Objectives
Detection of liver metastases is crucial for guiding oncological management. Computed tomography through iterative reconstructions is widely used in this indication but has certain limitations. Deep learning image reconstructions (DLIR) use deep neural networks to achieve a significant noise reduction compared to iterative reconstructions. While reports have demonstrated improvements in image quality, their impact on liver metastases detection remains unclear. Our main objective was to determine whether DLIR affects the number of detected liver metastasis. Our secondary objective was to compare metastases conspicuity between the two reconstruction methods.
Methods
CT images of 121 patients with liver metastases were reconstructed using a 50% adaptive statistical iterative reconstruction (50%-ASiR-V), and three levels of DLIR (DLIR-low, DLIR-medium, and DLIR-high). For each reconstruction, two double-blinded radiologists counted up to a maximum of ten metastases. Visibility and contour definitions were also assessed. Comparisons between methods for continuous parameters were performed using mixed models.
Results
A higher number of metastases was detected by one reader with DLIR-high: 7 (2–10) (median (Q₁–Q₃); total 733) versus 5 (2–10), respectively for DLIR-medium, DLIR-low, and ASiR-V (p < 0.001). Ten patents were detected with more metastases with DLIR-high simultaneously by both readers and a third reader for confirmation. Metastases visibility and contour definition were better with DLIR than ASiR-V.
Conclusion
DLIR-high enhanced the detection and visibility of liver metastases compared to ASiR-V, and also increased the number of liver metastases detected.
Critical relevance statement
Deep learning-based reconstruction at high strength allowed an increase in liver metastases detection compared to hybrid iterative reconstruction and can be used in clinical oncology imaging to help overcome the limitations of CT.
Key Points
-
Detection of liver metastases is crucial but limited with standard CT reconstructions.
-
More liver metastases were detected with deep-learning CT reconstruction compared to iterative reconstruction.
-
Deep learning reconstructions are suitable for hepatic metastases staging and follow-up.
Graphical Abstract
Introduction
Early detection of liver metastases plays a major role in management options and long-term prognosis and mostly relies on CT [1].
To obtain images from raw data, various algorithms can be used, with iterative reconstructions being the most widespread. Adaptive statistical iterative reconstruction-V (ASiR-V) (GE-HealthCare®) is a hybrid iterative reconstruction technique used in conjunction with filtered back projection in variable proportions according to user preferences. The measured value of each pixel is re-estimated and compared to an ideal predicted through an algebraic noise model. This process is repeated until there is concordance between the estimated and ideal values, thereby reducing noise while maintaining image quality [2].
Detection of liver metastases can be challenging, and CT through hybrid iterative reconstruction methods has certain limitations. It has been shown that using a high percentage of ASiR can lead to a lower image quality, giving it a plastic appearance or an unusually blurry texture, which limits the potential for noise reduction [3]. When comparing CT to MRI, 10% of liver metastases from pancreatic ductal carcinoma were missed [4], and up to 32% were noted as indeterminate [5]. Furthermore, CT scan has a low sensitivity for detecting lesions smaller than 10 mm [6].
Deep learning-based reconstructions are now available and aim to significantly reduce image noise [7, 8]. Deep learning image reconstruction (DLIR) TrueFidelity (GE-HealthCare®) is a new reconstruction method based on a convolutional neural network. The network was trained on thousands of high-quality CT datasets from patients and phantoms, acquired using filtered back projection. It enhances the raw data from a low-dose protocol by comparing it to the optimal data obtained during the training phase. Parameters such as noise, low-contrast resolution, and texture are analyzed and compared. The differences between the two datasets are minimized to achieve the best possible image. This process has been optimized through a learning phase [9]. Three selectable deep learning strength levels (DLIR-low, DLIR-medium, and DLIR-high) are configured by the manufacturer and available for use by clinicians to provide different amounts of noise reduction without impacting reconstruction speed.
These reconstructions provide high quality abdominal CT at same radiation doses compared to iterative reconstructions [10,11,12].
Several studies have investigated the benefits of DLIR for hepatic lesions. Jensen et al demonstrated that diagnostic confidence scores for abdominal lesions were significantly higher with DLIR compared to ASiR-V. However, their study included all solid organ lesions and did not specifically target hepatic metastases [13]. Nakamura et al found that DLIR resulted in higher scores for the conspicuity of hepatic metastases compared to adaptive iterative dose reduction 3D (AiDR 3D, Canon Medical System®) [14]. However, they did not assess lesion detection. Singh et al showed that DLIR was equivalent to AiDR for the detection of abdominal lesions in a prospective multi-institutional study [15]. Of the 31 lesions evaluated, only 13 were low-attenuating hepatic lesions, which limits the ability to draw definitive conclusions regarding metastasis detection. Therefore, the impact of DLIR on hepatic metastases detection remains unclear.
We hypothesized that the image enhancement from these new reconstruction techniques could allow an increased detection of liver metastases compared to conventional iterative reconstructions. Our main objective was to compare the number of metastases detected using three different levels of DLIR and a 50%-ASiR-V. Our secondary objective was to compare metastases conspicuity for each reconstruction.
Methods
This was a retrospective observational single institutional study conducted in our medical imaging department.
Patient selection
All CT scans of the abdomen and pelvis performed for cancer initial assessment or follow-up between November 2020 and July 2021 were selected for the inclusion process. The inclusion criterion was the presence of at least one hypoattenuating liver metastasis described in the radiology report. Exclusion criteria were the loss of at least one reconstruction (loss of raw data, at least one reconstruction not saved on picture archiving and communication system (PACS)), double energy acquisition, age less than 18 years old, hypervascular metastases, and absence of histopathological proof of cancer.
Imaging technique and CT reconstructions
CT scans were performed using the same Revolution Evo system (GE-HealthCare®) at 120 kV tube, 160 to 500 mA current range with organ dose modulation, 1.375 pitch, 40 mm detector collimation, 0.70 second rotation time, and 1.25 mm thickness. Iodine contrast material was administered with a basis of 2 mL per kilogram adapted to body weight (mean 93 ± 10 mL; range 80-130 mL) (Xenetix 350, Guerbet or Omnipaque 350) into the cubital vein at an injection rate of 2 mL per second. The acquisition was performed 90 seconds after injection. Volume computed tomography dose index (CTDIVOL) and dose length product (DLP) were recorded.
One standard 50%-ASiR-V reconstruction and three deep-learning reconstructions were obtained using the DLIR algorithm TrueFidelity at different strength levels: DLIR-low (DLIR-L), DLIR-medium (DLIR-M), and DLIR-high (DLIR-H). All CT scans were anonymized before analysis.
CT analysis and lesion detection
Metastases number evaluation and subjective analyses and were performed independently by Reader 1, A.K., with three years of in-training experience in radiology, and Reader 2, B.C., with ten years of experience in abdominal radiology. Readers were blinded to the reconstruction method and the patient past medical history. Both readers received identical and standardized printed instructions before evaluation. All CT scans were randomly split into four equal blocks, each block containing one random reconstruction method by patients (121 scans per block). CT scans were analyzed block by block in a random and different order from July to December 2021. To avoid memory bias, an interval of one month between each block analysis was respected. The evaluation was performed on an Advantage Workstation (AW3.2, GE-HealthCare®). Readers were able to adjust the window (width and level) and use coronal or sagittal sections and minimum intensity projection as desired.
Both readers counted the number of hepatic metastases from 0 to a maximum of 10. In cases where both readers found more metastases with DLIR-H than ASiR-V or vice versa, a third independent radiologist (B.M.), with 11 years of experience in abdominal radiology, blindly evaluated the number of lesions on both reconstructions to confirm or disprove the difference. In case of discrepancies, an unblinded consensus reading was made by the three readers. They used all available data, such as MRIs, previous or subsequent CT scans, and clinical reports to verify the metastatic nature of missed lesions, mainly based on their MRI signal characteristics or size variation over time.
Both readers rated overall image quality, image noise reduction, hepatic metastases visibility and hepatic metastases contour definition using a five-point scale: 1-inacceptable; 2-low; 3-medium; 4-good; 5-excellent, based on their own subjectivity.
Attenuation measurements
Measurements were performed by reader 1, using an Advantage Workstation. Regions of interest (ROIs) were placed on nine anatomical structures (Table 1) and at the center of one randomly selected hepatic metastasis, avoiding artifacts and irregularities. The ROI was then cloned at the same location for each reconstruction. Image noise (N) was defined as the standard deviation of attenuation in the paraspinal muscle. The contrast-to-noise ratio (CNR) of a structure was calculated as the absolute difference between its mean attenuation and the mean attenuation of paraspinal muscle divided by image noise CNRa = │HUa- HUmuscle│/N, (HU: Hounsfield unit).
Statistical analysis
Continuous variables were expressed according to their statistical distribution with mean and standard deviation (SD). Metastasis number was, however expressed as median and interquartile range. An arbitrary limit of 10 lesions was given, and the mean number of lesions seemed less appropriate to be presented as a result. Agreement (between both readers and between reconstruction methods) was assessed using Lin’s concordance correlation coefficient. The results were interpreted in relation to recommendations reported in the literature by Altman: < 0.4: no agreement, 0.4–7: poor agreement, > 0.7: moderate to strong agreement [16]. Comparisons between methods for continuous variables were completed using mixed models that allowed to consider between- and within-patient variability (i.e., subject as a random effect). The normality of residuals from these models was analyzed with the Shapiro‒Wilk test and graphical presentation. When appropriate, a logarithmic transformation of the dependent variable has been applied. Statistical analyses were performed using Stata software (version 15, StataCorp, College Station) by B.P. All statistical tests were carried out based on a two-sided type I error at 5%. Sidak’s type I error correction was applied for two-by-two multiple comparisons between methods.
Results
Patient and lesion characteristics
A total of 121 patients were included in the study. A flow chart of the inclusion process is shown in Fig. 1. Patients and primitive tumor characteristics are listed in Table 2.
Lesion detection
A higher number of metastases was detected by the senior reader (R2) with DLIR-high: 7 (2–10) (median (Q₁–Q₃); total 733) versus 5 (2–10) respectively for DLIR-medium, DLIR-low, and ASiR-V (p < 0.001) (Table 3). The junior reader (R1) found no significant difference in metastases number between reconstructions.
For 12 patients, both readers simultaneously found a higher number of metastases with DLIR-H compared to ASiR-V. This was confirmed for ten patients by the third radiologist and disproved for the other two patients (Figs. 2 and 3). Consensus reading was allowed by comparison with subsequent MRI for three patients, subsequent CT for three patients, and previous CT for four patients. In these cases, one additional metastasis was detected using DLIR-H in six patients, and two in four patients. This led to 14 missed lesions with a median size of 7 mm. (details available in Appendix 1).
For two patients, both readers detected a higher number of metastases with ASiR-V than DLIR-H. Confirmation with the third radiologist was obtained for one patient only with consensus reading using a subsequent MRI. The missed lesion was 11 mm in size (Fig. 4).
CT subjective analysis
Image quality and noise reduction were lower for ASiR-V and increased with deep learning levels (Fig. 5a). Significant differences were observed between all reconstructions for both readers (p < 0.001). Metastases visibility and contour definition were better for DLIR-H compared to other reconstructions for both readers (Fig. 5b).
Attenuation measurements
Image noise was significantly higher for DLIR-L, followed by ASiR-V, DLIR-M, and DLIR-H (p < 0.001). CNRs of anatomical structures were significantly different between all reconstructions, with the highest values for DLIR-H followed by DLIR-M, ASiR-V and DLIR-L (p < 0.001). CNRs of metastases were higher using DLIR-H and DLIR-M compared to ASiR-V (p < 0.001) (Table 1).
Radiation dose
Mean CTDIVOL and DLP were 9,2 mGy ± 2,5 and 512 mGy.cm ± 158, respectively.
Discussion
This study aimed to compare a recent deep learning-based reconstruction (TrueFidelity) and a standard iterative reconstruction (50%-ASiR-V) for the detection of hypoattenuating liver metastases on CT. The main objective was to determine whether DLIR would affect the number of detected lesions. High-strength DLIR led to a statistical increase in the number of detected lesions for one of the two readers. Additionally, high-strength DLIR enabled both readers to simultaneously detect more metastases in ten patients compared to ASiR-V. This statement was confirmed by a third independent reader. As a secondary objective, we compared lesion conspicuity between both reconstructions. The visibility and contour definition of hepatic metastases received better scores with DLIR-high compared to the other reconstructions for both readers.
The most common etiologies of liver metastases arise from the gastrointestinal tract, mainly colorectal and pancreatic cancers [17]. Management of patients depends on the presence of liver metastases. Their number, size, and location can guide clinicians toward curative or conservative techniques. Treatment modalities include resection surgeries, thermoablation procedures, stereotactic radiotherapy, endovascular treatments, or systemic therapies [18]. Many techniques can be used for liver metastases detection as a conjunct to the initial CT staging. MRI seems to be superior to CT scan, especially for < 10 mm lesions [6, 19]. Fluorine-18-fluorodeoxyglucose positron emission tomography/CT (PET/CT) is also very sensitive but has limited performances for small lesions [20]. Other techniques have been evaluated, such as Kupffer-phase imaging in contrast-enhanced endoscopic ultrasonography, with superior results for small left liver metastases [21].
Liver metastases of digestive adenocarcinoma often appear as multiple hypoattenuating nodular lesions. As adenocarcinomas represented 74% of our study population, comparison between reconstructions were performed on a homogeneous pool of lesions. Imaging features may however change, based on histopathological characteristics and may moderate interpretation of the results. For example, desmoplastic reactions around colorectal liver metastases are closely related to peripheral enhancement [22]. Cystic components of primary tumor and severe necrosis can lead to cyst-like hepatic metastases. Other characteristics may be present, such as calcifications in mucinous adenocarcinoma, and peripheral wash-out and hypervascularity in neuro-endocrine tumors [23].
Despite the multiple modalities, CT scan remains the gold standard for gastro-intestinal cancer staging and follow up according to international recommendations. The current protocol often involves a CT scan of thorax, abdomen, and pelvis [24,25,26]. Obtaining high-quality images is therefore essential and implementation of artificial intelligence-based reconstruction algorithms facilitate early detection of metastases.
Deep learning methods still have certain limitations. Kaga et al showed that high levels of deep learning can reduce the conspicuity of hepatic lesions compared to ASiR-V, especially for small lesions [27]. This was also described for extrahepatic exploration such as chest CT, where small structures had lower conspicuity scores with high-strength DLIR [28]. Yang et al found no difference in liver lesion detection between DLIR and ASIR-V; however, they only involved 8 patients and 13 malignant lesions in their analysis [29].
There have been recent studies experimenting different low-dose protocols of DLIR in terms of quality assessment of images and lesion detection [30,31,32,33,34,35,36]. Wang et al found that low-dose deep learning algorithms may provide better images, signal-to-noise, and contrast-to-noise ratios of unenhanced CT scans when compared to standard-dose iterative reconstruction. They found no difference in sensitivity and diagnostic confidence for liver metastases detection [37]. When comparing a 33%-dose protocol with DLIR to a standard-dose iterative reconstruction, Lee et al found lower noise on DLIR and comparable diagnostic performance in detecting malignant liver tumors [38].
The aim of our study was to determine whether diagnostic performance was superior at the same dose level, specifically if more hepatic metastases could be detected. To our knowledge, no study has yet described an increase in the number of detected hepatic metastases using deep learning reconstructions compared to iterative reconstructions. This finding could significantly impact patients’ oncologic evaluation. Our study showed that more metastases were detected in 10 out of 121 patients with DLIR. As expected, the majority of missed lesions were smaller than 10 mm, as subcentimeter lesions can often be missed on CT scans [3]. Detecting these small lesions can significantly influence the therapeutic management of patients, such as surgical or ablative planning in colorectal cancer, or a switch from curative to palliative care in pancreatic adenocarcinoma.
Our study has some limitations. First, this was a retrospective study, relying on a single CT and one manufacturer’s DLIR. Second, our inclusion criterion was solely based on the final CT report with no prior confirmation of our own. However, all cases had histopathological proof of the primary cancer. Most of the patients had previous MRIs, which were used for comparison by radiologists allowing reduction of potential selection bias. We only included patients with liver metastases, which suggests that our results showed DLIR to increase sensitivity rather than specificity for lesion detection. Finally, we did not perform subgroup analyses based on primary tumor type.
Although our study doesn’t evaluate patient management and outcome, our results suggest a potential implication of DLIR and can be considered as an aid in selecting the most appropriate CT reconstruction and the level of deep learning for liver metastases detection. In conclusion, high-strength DLIR statistically increased the detection and conspicuity of liver metastases compared to ASiR-V. Additional studies should be conducted to assess the clinical impact of these findings, but our results encourage the use of deep-learning reconstructions when performing abdominal CT scans in oncology.
Data availability
The CT scans analyzed during the current study are not publicly available to protect study participant privacy according to local legislation. The anonymized analyzed data are available from the corresponding author upon reasonable request.
Abbreviations
- ASiR-V:
-
Adaptive Statistical Iterative Reconstruction-V
- CNR:
-
Contrast-to-Noise Ratio
- CTDIVOL :
-
Computed Tomography Dose Index
- DLIR:
-
Deep Learning Image Reconstruction
- DLIR-H:
-
Deep Learning Image Reconstruction High
- DLIR-L:
-
Deep Learning Image Reconstruction Low
- DLIR-M:
-
Deep Learning Image Reconstruction Medium
- DLP:
-
Dose Length Product
References
Germani MM, Borelli B, Boraschi P et al (2022) The management of colorectal liver metastases amenable of surgical resection: How to shape treatment strategies according to clinical, radiological, pathological and molecular features. Cancer Treat Rev 106:102382. https://doi.org/10.1016/j.ctrv.2022.102382
Tayal U, King L, Schofield R et al (2019) Image reconstruction in cardiovascular CT: Part 2 – Iterative reconstruction; potential and pitfalls. J. Cardiovasc. Comput. Tomogr 13:3–10. https://doi.org/10.1016/j.jcct.2019.04.009
Padole A, Ali Khawaja RD, Kalra MK, Singh S (2015) CT radiation dose and iterative reconstruction techniques. AJR Am J Roentgenol 204:W384–W392. https://doi.org/10.2214/AJR.14.13241
Marion-Audibert A-M, Vullierme M-P, Ronot M et al (2018) Routine MRI with DWI sequences to detect liver metastases in patients with potentially resectable pancreatic ductal carcinoma and normal liver CT: a prospective multicenter study. AJR Am J Roentgenol 211:W217–W225. https://doi.org/10.2214/AJR.18.19640
Kim HW, Lee J-C, Paik K-H et al (2017) Adjunctive role of preoperative liver magnetic resonance imaging for potentially resectable pancreatic cancer. Surgery 161:1579–1587. https://doi.org/10.1016/j.surg.2016.12.038
Tsili AC, Alexiou G, Nakal C, Argyropoulou MI (2021) Imaging of colorectal cancer liver metastases using contrast-enhanced US, multidetector CT, MRI, and FDG PET/CT: a meta-analysis. Acta Radiol 62:302–312. https://doi.org/10.1177/0284185120925481
McLeavy CM, Chunara MH, Gravell RJ et al (2021) The future of CT: deep learning reconstruction. Clin Radiol 76:407–415. https://doi.org/10.1016/j.crad.2021.01.010
Boedeker K (2019) AiCE Deep Learning Reconstruction: Bringing the power of Ultra-High Resolution CT to routine imaging. Available via https://fr.medical.canon/wp-content/uploads/sites/21/2019/11/White-paper-Kirsten-Boedeker.pdf. Accessed 3rd March 2024
Hsieh J, Liu E, Nett B, Tang J, Thibault J-B, Sahney S (2019) A new era of image reconstruction: TrueFidelity - Technical white paper on deep learning image reconstruction. Available via https://www.gehealthcare.com/-/jssmedia/040dd213fa89463287155151fdb01922.pdf. Accessed 3rd March 2024
Akagi M, Nakamura Y, Higaki T et al (2019) Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT. Eur Radiol 29:6163–6171. https://doi.org/10.1007/s00330-019-06170-3
Park C, Choo KS, Jung Y, Jeong HS, Hwang J-Y, Yun MS (2021) CT iterative vs deep learning reconstruction: comparison of noise and sharpness. Eur Radiol 31:3156–3164. https://doi.org/10.1007/s00330-020-07358-8
Ichikawa Y, Kanii Y, Yamazaki A et al (2021) Deep learning image reconstruction for improvement of image quality of abdominal computed tomography: comparison with hybrid iterative reconstruction. Jpn J Radiol 39:598–604. https://doi.org/10.1007/s11604-021-01089-6
Jensen CT, Liu X, Tamm EP et al (2020) Image quality assessment of abdominal CT by use of new deep learning image reconstruction: initial experience. AJR Am J Roentgenol 215:50–57. https://doi.org/10.2214/AJR.19.22332
Nakamura Y, Higaki T, Tatsugami F et al (2021) Deep learning–based CT image reconstruction: initial evaluation targeting hypovascular hepatic metastases. Radiol Artif Intell 1:e180011. https://doi.org/10.1148/ryai.2019180011
Singh R, Digumarthy SR, Muse VV et al (2020) Image quality and lesion detection on deep learning reconstruction and Iterative reconstruction of submillisievert chest and abdominal CT. AJR Am J Roentgenol 214:566–573. https://doi.org/10.2214/AJR.19.21809
Altman DG (1990) Practical statistics for medical research. Chapman and hall, New York https://doi.org/10.1201/9780429258589
Horn SR, Stoltzfus KC, Lehrer EJ et al (2020) Epidemiology of liver metastases. Cancer Epidemiol 67:101760. https://doi.org/10.1016/j.canep.2020.101760
Cervantes A, Adam R, Roselló S et al (2023) Metastatic colorectal cancer: ESMO Clinical Practice Guideline for diagnosis, treatment and follow-up. Ann Oncol 34:10–32. https://doi.org/10.1016/j.annonc.2022.10.003
Renzulli M, Clemente A, Ierardi AM et al (2020) Imaging of Colorectal Liver Metastases: New Developments and Pending Issues. Cancers 12:151. https://doi.org/10.3390/cancers12010151
Serrano PE, Gu C-S, Moulton C-A et al (2020) Effect of PET‐CT on disease recurrence and management in patients with potentially resectable colorectal cancer liver metastases. Long‐term results of a randomized controlled trial. J Surg Oncol 121:1001–1006. https://doi.org/10.1002/jso.25864
Minaga K, Kitano M, Nakai A et al (2021) Improved detection of liver metastasis using Kupffer-phase imaging in contrast-enhanced harmonic EUS in patients with pancreatic cancer (with video). Gastrointest Endosc 93:433–441. https://doi.org/10.1016/j.gie.2020.06.051
Eble JA, Niland S (2019) The extracellular matrix in tumor progression and metastasis. Clin Exp Metastasis 36:171–198. https://doi.org/10.1007/s10585-019-09966-1
Ozaki K, Higuchi S, Kimura H, Gabata T (2022) Liver Metastases: Correlation between Imaging Features and Pathomolecular Environments. Radiographics 42:1994–2013. https://doi.org/10.1148/rg.220056
National Comprehensive Cancer Network. NCCN Clinical Practice Guidelines in Oncology Colon Cancer Version 1 (2020) Available via https://www.nccn.org/professionals/physician_gls/pdf/colon.pdf. Accessed 20 May 2024.
Haria PD, Baheti AD, Palsetia D et al (2021) Follow-up of colorectal cancer and patterns of recurrence. Clin Radiol 76:908–915. https://doi.org/10.1016/j.crad.2021.07.016
Daamen LA, Groot VP, Intven MPW et al (2019) Postoperative surveillance of pancreatic cancer patients. Eur J Surg Oncol 45:1770–1777. https://doi.org/10.1016/j.ejso.2019.05.031
Kaga T, Noda Y, Fujimoto K et al (2021) Deep-learning-based image reconstruction in dynamic contrast-enhanced abdominal CT: image quality and lesion detection among reconstruction strength levels. Clin Radiol 76:710.e15–710.e24. https://doi.org/10.1016/j.crad.2021.03.010
Tian Q, Li X, Li J et al (2022) Image quality improvement in low-dose chest CT with deep learning image reconstruction. J Appl Clin Med Phys 23:e13796. https://doi.org/10.1002/acm2.13796
Yang S, Bie Y, Pang G et al (2021) Impact of novel deep learning image reconstruction algorithm on diagnosis of contrast-enhanced liver computed tomography imaging: Comparing to adaptive statistical iterative reconstruction algorithm. J Xray Sci Technol 29:1009–1018. https://doi.org/10.3233/XST-210953
Nakamura Y, Narita K, Higaki T, Akagi M, Honda Y, Awai K (2021) Diagnostic value of deep learning reconstruction for radiation dose reduction at abdominal ultra-high-resolution CT. Eur Radiol 31:4700–4709. https://doi.org/10.1007/s00330-020-07566-2
Lyu P, Liu N, Harrawood B et al (2022) Is it possible to use low-dose deep learning reconstruction for the detection of liver metastases on CT routinely? Eur Radiol 33:1629–1640. https://doi.org/10.1007/s00330-022-09206-3
Toia GV, Zamora DA, Singleton M et al (2023) Detectability of Small Low-Attenuation Lesions With Deep Learning CT Image Reconstruction: A 24-Reader Phantom Study. AJR Am J Roentgenol 220:283–295. https://doi.org/10.2214/AJR.22.28407
Lyu P, Li Z, Chen Y et al (2024) Deep learning reconstruction CT for liver metastases: low-dose dual-energy vs standard-dose single-energy. Eur Radiol 34:28–38. https://doi.org/10.1007/s00330-023-10033-3
Jensen CT, Gupta S, Saleh MM et al (2022) Reduced-Dose Deep Learning Reconstruction for Abdominal CT of Liver Metastases. Radiology 303:90–98. https://doi.org/10.1148/radiol.211838
Steuwe A, Weber M, Bethge OT et al (2020) Influence of a novel deep-learning based reconstruction software on the objective and subjective image quality in low-dose abdominal computed tomography. Br J Radiol 94:20200677. https://doi.org/10.1259/bjr.20200677
Cao L, Liu X, Li J et al (2021) A study of using a deep learning image reconstruction to improve the image quality of extremely low dose contrast-enhanced abdominal CT for patients with hepatic lesions. Br J Radiol 94:20201086. https://doi.org/10.1259/bjr.20201086
Wang X, Zheng F, Xiao R et al (2021) Comparison of image quality and lesion diagnosis in abdominopelvic unenhanced CT between reduced-dose CT using deep learning post-processing and standard-dose CT using iterative reconstruction: A prospective study. Eur J Radiol 139:109735. https://doi.org/10.1016/j.ejrad.2021.109735
Lee DH, Lee JM, Lee CH, Afat S, Othman A (2024) Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT. Radiol Artif Intell 6:e230192. https://doi.org/10.1148/ryai.230192
Acknowledgements
The authors would like to thank Helen Braund for language editing and Anthony Aufaure for his help.
Funding
The authors received no specific funding for the study.
Author information
Authors and Affiliations
Contributions
A.K. contributed to the literature search, conceptualization, collection, C.T. reading, data analysis, data interpretation, manuscript edition, and validation of the study. B.P. contributed to the literature search, conceptualization, data analysis, data interpretation, and manuscript edition. C.H. contributed to the literature search, conceptualization, collection, data analysis, data interpretation, and manuscript edition. L.C. contributed to the literature search, conceptualization, collection, data interpretation, and manuscript edition. E.P. contributed to the literature search, conceptualization, collection, data interpretation, and manuscript edition. L.T. contributed to the literature search, conceptualization, collection, data interpretation, and manuscript edition. B.C. contributed to the literature search, conceptualization, collection, C.T. reading data analysis, data interpretation, manuscript edition, validation of the study, and study supervision. B.M. contributed to the literature search, conceptualization, collection, C.T. reading data analysis, data interpretation, manuscript edition, validation of the study, and study supervision. All the authors have read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
This study was approved by the Ethical Committee for Research in Medical Imaging (n° CRM-2203-250), which waived patients’ prior written consent due to the retrospective design of the study.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher’s Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Kanan, A., Pereira, B., Hordonneau, C. et al. Deep learning CT reconstruction improves liver metastases detection. Insights Imaging 15, 167 (2024). https://doi.org/10.1186/s13244-024-01753-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s13244-024-01753-1