Table 5 Intraclass correlation coefficient (ICC) obtained for all the measurements for the inter- and intra-reader reliability of synthetic CT (sCT) and CT

From: MRI-based synthetic CT for assessment of the bony elements of the sacroiliac joints in children

 

Inter-reader reliability

Intra-reader reliability

Measurement

sCT

CT

sCT

CT

Maximum diagonal width of vertebral body S1

0.994

0.982

0.995

0.993

Maximum diagonal height of vertebral body S1

0.991

0.962

0.995

0.975

Maximum diagonal width of vertebral body S2

0.979

0.914

0.996

0.977

Maximum diagonal height of vertebral body S2

0.955

0.909

0.982

0.984

Maximum height of the intervertebral disc space

0.945

0.966

0.806

0.946

Maximum spinal canal width

0.996

0.994

0.998

0.995