Skip to main content

Table 1 Comparisons of the attenuation and noise of vessel and artifact

From: Optimal combination periprosthetic vasculature visualization and metal artifact reduction by spectral computed tomography using virtual monoenergetic images in total hip arthroplasty

 

CI

CIMAR

                                                                                                VMIMAR

50 keV

60 keV

70 keV

80 keV

90 keV

100 keV

110 keV

120 keV

Attenuation (HU)

 Vessel

387.26 ± 73.65

302.17 ± 62.81

542.52 ± 136.87

390.50 ± 90.73

299.15 ± 66.07

242.06 ± 53.50

204.77 ± 47.69

179.41 ± 45.25

161.55 ± 44.37

148.59 ± 44.28

 Artifact

696.04 ± 218.17

490.82 ± 181.42

747.31 ± 281.64

581.37 ± 204.93

522.28 ± 174.86

469.36 ± 162.21

434.85 ± 158.17

411.86 ± 156.53

395.36 ± 157.14

383.38 ± 158.12

Noise

 Vessel

37.42 ± 18.57

45.34 ± 27.78

64.61 ± 50.01

49.83 ± 34.86

41.36 ± 26.08

36.31 ± 20.97

33.20 ± 17.92

31.12 ± 15.99

29.79 ± 14.81

28.86 ± 14.01

 Artifact

122.92 ± 53.34

82.08 ± 33.07

125.37 ± 64.79

116.57 ± 105.37

88.76 ± 37.15

80.68 ± 32.42

75.55 ± 29.99

72.0 ± 28.51

69.70 ± 27.75

68.08 ± 27.28

Width of artifact (mm)

48.51 ± 16.33

28.74 ± 9.97

35.93 ± 12.68

33.47 ± 12.11

29.25 ± 10.49

26.76 ± 10.37

25.53 ± 10.59

23.89 ± 10.61

22.91 ± 10.63

22.41 ± 10.69