Skip to main content

Table 3 Performance comparison of the clinical model, radiomics signature, and radiomics nomogram in the training and external validation cohorts

From: A CT-based radiomics approach to predict intra-tumoral tertiary lymphoid structures and recurrence of intrahepatic cholangiocarcinoma

Model

Training cohort (n = 86)

External validation cohort (n = 30)

Clinical model

 Sensitivity

0.76

0.80

 Specificity

0.80

0.76

 Accuracy

0.79

0.77

 AUC (95% CI)

0.75 (0.63–0.87)

0.71 (0.48–0.93)

Radiomics model

 Sensitivity

0.89

1.0

 Specificity

0.69

0.70

 Accuracy

0.76

0.80

 AUC (95% CI)

0.82 (0.73–0.91)

0.86 (0.74–0.99)

Radiomics nomogram

 Sensitivity

0.57

0.60

 Specificity

0.93

0.93

 Accuracy

0.76

0.77

 AUC (95% CI)

0.85 (0.78–0.93)

0.88 (0.76–1.00)