Table 1 Summary of studies evaluating ECV quantification with CT, detailing scan, reconstruction, and contrast media protocols

From: Myocardial extracellular volume quantification with computed tomography—current status and future outlook

 

Scanner type

Non-enhanced scan

Timing of LE scan [min]

Slice thickness/

Tube voltage

ECG-gating

Contrast media [mgI/mL]

Dose of contrast media

Effective radiation dosea

Single-energy protocols

 Nacif, 2012 [14]

Aquilion One (Toshiba)

Yes

10

3 mm

120 kVp

Prospective

Iopamidol (370)

Bolus of 125 mL ± 24 mL

1.98 ± 0.16 mSv for non-enhanced and LE scan

 Bandula, 2013 [12]

Somatom Sensation 64 (Siemens)

Yes

25

5 mm

120 kVp

Retrospective

Iohexol (300)

Bolus of 1 mL/kg body weight + infusion of 1.88 mL/kg/h

10.7 ± 3.4 mSv (total cardiac CT protocol)

 Hamdy, 2018 [20]

Somatom Force (Siemens)

Yes

3, 5, 7

1 mm

80 kVp

Prospective

Iopamiron (370)

Bolus of 1.6 mL/kg body weight

11.8 ± 2.9 mSv (total cardiac CT protocol)

 Scully, 2020 [21]

Somatom Force (Siemens)

Yes

3, 5

2 mm

80 kVp

Prospective

Iohexol (300)

Bolus of 90 mL

5.1 ± 0.3 mSv for non-enhanced and LE scan

 Tamarappoo, 2020 [10]

Somatom Definition Flash (Siemens)

Yes

5

3 mm

120 kVp

Prospective

Iohexol (350)

Bolus of 100 mL

25.7 ± 6.9 mSv (total cardiac CT protocol)

Dual-energy protocols

 Lee, 2016 [18]

Somatom Definition Flash (Siemens)

No

12

0.75 mm

100/140 kVp

Retrospective

Iopamidol (370)

Bolus of 1.8 mL/kg body weight

5.59 ± 0.85 mSv (total cardiac CT protocol)

 Abadia, 2019 [15]

Somatom Force (Siemens Healthcare)

No

7

1.5 mm

90/150 kVp

Prospective

Iopamidol (370)

Bolus of 65 mL

3.61 mSv [2.78–4.21] (total cardiac CT protocol)

 Oda, 2019 [22]

iQon Spectral CT (Philips)

No

7

0.67 mm

120 kVp

Prospective

Iopamidol (370)

Bolus of 1.5 mL/kg body weight

4.8 ± 1.6 mSv for LE scan

 Ohta, 2020 [23]

Discover CT 750 HD (GE)

No

7–8

0.625 mm

80/140 kVp

Prospective

Iopamidol (370)

Bolus of 0.9 mL/kg body weight + infusion until 1.4 mL/kg/scan

3.42 ± 0.87 mSv for LE scan

 Dubourg, 2021 [17]

Discover CT 750HD (G)

No

7

0.625 mm

80/140 kVp

Prospective

Iohexol (350)

Bolus of 65 mL

1.89 ± 0.38 mSv for LE scan

 Qi, 2022 [24]

Somatom Force (Siemens)

No

7

0.6 mm

90/150 kVp

Prospective

Iopromide (370)

Two boli of 50 mL + 50 mL

5.9 mSv [4.5–8.4] (total cardiac CT protocol)

Photon-counting detector CT scanner

 Mergen, 2022 [25]

NAEOTOM Alpha (Siemens)

Yes

5

1.5 mm

120 kVp

Prospective

Iopromide (370)

Bolus of 100 mL

1.2 mSv [0.97–1.75] for LE scan

  1. LE Late enhancement
  2. aEffective radiation dose was calculated by multiplying the DLP by a factor of 0.014, if not available in the publication