Skip to main content

Table 2 Exposure settings and radiation dose of included studies

From: Dynamic chest radiography: a state-of-the-art review

Author

Duration (s)

ESD (mGy)

Frame rate (fps)

Tanaka et al. [8]

10

0.4

3

Tanaka et al. [4]

10

0.4

3

Tanaka et al. [9]

10

0.4

3

Tanaka et al. [10]

4

0.32

6

Kawashima et al. [11]

8

NA

7.5

Tanaka et al. [12]

4

0.6

7.5

Tanaka et al. [5]

4

0.6

7.5

Tsuchiya et al. [13]

10

0.4

3

Tanaka et al. [14]

8

0.6

7.5

Tanaka et al. [15]

10

0.4

3

Yamada et al. [16]

10.0–15.0

0.3–0.5

15

Tanaka et al. [17]

14

NA

15

Yamada et al. [18]

10.0–15.0

0.3–1

7.5–30

Yamada et al. [19]

10.0–15.0

0.3–1

7.5

Hida et al. [20]

17–37

0.3–1

15

Hida et al. [21]

10.0–15.0

0.3–1

7.5–15

Kitahara et al. [22]

10

NA

15

Hanaoka et al. [23]

10

1.5

15

Hino et al. [24]

10.0–15.0

0.3–1

15

Ohkura et al. [25]

14

EED: 0.21 mSv

15

Tanaka et al. 2020 [26]

NA

 < 1.9

15

Watase et al. 2020 [27]

15

1.3

15

Yamamoto et al. 2020 [28]

6.0–14.0

1–1.8

15

FitzMaurice et al. 2022 [29]

10

EED: 0.13 mSv

15

FitzMaurice et al. 2022 [30]

20

EED: 0.25 mSv

15

Ohkura et al. 2021 [31]

14

EED: 0.2 mSv

15

Tanaka et al. 2021 [32]

14

 < 1.9

15

Ueyama et al. 2021 [33]

18.3–19.6

1.5–4

15

FitzMaurice et al. 2022 [34]

10

EED: 0.13 mSv

15

  1. ESD entrance surface dose [of radiation], EED estimated effective dose[of radiation]