From: CT volume analysis in living donor liver transplantation: accuracy of three different approaches
Application | Difference (mL) | Error ratio (%) |
---|---|---|
Volume analysis | Â | Â |
Median | 42.2 | 6.9 |
25th percentile | − 8.5 | 3.8 |
75th percentile | 95.1 | 14.6 |
OsiriX MD | Â | Â |
Median | 42.2 | 12.5 |
25th percentile | 17.8 | 5.5 |
75th percentile | 144.2 | 21.7 |
CT liver analysis | Â | Â |
Median | 55.9 | 9.9 |
25th percentile | 0.2 | 4.8 |