Skip to main content

Table 3 Diagnosis performance on cervical cancer of histogram-derived scanned and synthetic 13b-protocol ADC values with a b value of 0 and 1200 s/mm2

From: A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors

Parameters

AUC (95%CI)

Sensitivity (%)

Specificity (%)

p value

Threshold (s/mm2)

sADC13b,mean

0.995 (0.987–1.000)

100.0

94.4

p < 0.05

0.903 × 10–3

syADC13b,mean

0.995 (0.985–1.000)

97.2

97.2

p < 0.05

0.941 × 10–3

sADC13b,minimum

0.956 (0.716–0.909)

91.7

88.9

p < 0.05

0.573 × 10–3

syADC13b,minimum

0.961 (0.921–1.000)

94.4

88.9

p < 0.05

0.633 × 10–3

sADC13b,skewness

0.463 (0.328–0.598)

91.7

16.7

p = 0.33

 − 0.515

syADC13b,skewness

0.485 (0.349–0.620)

55.6

55.6

p = 0.34

 − 0.067

sADC13b,kurtosis

0.439 (0.300–0.579)

97.2

22.2

p = 0.30

 − 0.793

syADC13b,kurtosis

0.485 (0.349–0.621)

11.1

97.2

p = 0.35

 − 0.564

  1. p values < 0.05 were considered statistically significant and are shown in bolded font
  2. AUC = area under the receiver operating characteristic curve, 95%CI = 95% confidence intervals, sADC = scanned apparent diffusion coefficient, syADC = synthetic apparent diffusion coefficient