Skip to main content

Table 1 The details of the CTA acquisition

From: A novel computed tomography angiography technique: guided preoperative localization and design of anterolateral thigh perforator flap

Parameter

 

Nitroglycerin

Sublingual (0.1 mg per dose)

Detector collimation (mm)

96 × 2 × 0.6

Gantry rotation time (s/r)

0.5

Tube voltage (kV)

80

Tube current modulation

Automated tube current (CARE Dose 4D)

Matrix

512 × 512

Pitch

0.35

Vision (mm2)

 ≤ 170

Convolution reconstruction kernel

Br54

Iterative reconstruction

ADMIRE (strength 5)

Slice thickness (mm)

0.75

Slice increment (mm)

0.3

Bolus-tracking monitoring section

The middle segment of the descending branch with a “manual” trigger mode

Injection speed (ml/s)

6–7.5

Contrast agent volume (ml)

90–112.5