Skip to main content

Table 2 Summarized similarity metrics for all radiologists and all structures (WG vs. TZ, and WG divided along cranio-caudal axis in base, mid-gland and apex), with 2 methods (pair-wise comparison and consensus comparison (STAPLE reference))

From: Challenge of prostate MRI segmentation on T2-weighted images: inter-observer variability and impact of prostate morphology

Structure

Method

DSC

HD (voxels)

AHD (voxels)

WG

Pairwise

0.92 ± 0.02

9.77 ± 3.78

0.17 ± 0.08

TZ

 

0.88 ± 0.05

11.98 ± 4.92

0.31 ± 0.19

WG

STAPLE

0.94 ± 0.03

8.15 ± 3.33

0.11 ± 0.07

TZ

 

0.91 ± 0.05

10.03 ± 4.25

0.21 ± 0.16

Base

Pairwise

0.87 ± 0.06

9.66 ± 4.61

 

Mid-gland

 

0.95 ± 0.02

7.51 ± 3.63

 

Apex

 

0.90 ± 0.06

7.12 ± 3.73

 

Base

STAPLE

0.91 ± 0.06

7.87 ± 3.69

 

Mid-gland

 

0.96 ± 0.02

6.10 ± 3.05

 

Apex

 

0.93 ± 0.05

5.88 ± 3.05