Table 1 State-of-the-art MRI protocol for comprehensive study of the female pelvis. Synoptic table summarizes the pulse sequence parameters. If not contraindicated, preliminary intramuscular or intravenous administration of an antispasmodic agent (e.g. N-butyl-scopolamine) may be performed. Axial T2-weighted SSFSE sequence is used as a second localiser. Sagittal T2-weighted FRFSE sequence is planned parallel to the long axis of the uterus, identified on the axial T2-weighted SSFSE sequence. Oblique-coronal and oblique-axial T2-weighted FRFSE sequences are planned parallel and perpendicular to the long axis of the uterus, respectively. Sagittal, oblique-coronal and oblique-axial T1-weighted 3D gradient-echo liver acquisition with volume acceleration (LAVA) sequences with fat suppression are obtained before and after intravenous administration of gadolinium-based contrast agent (0.1 mmol/kg, followed by 20 ml of saline solution, both at a 2 ml/s flow rate); in particular, the sagittal sequence is acquired at 60 and 120 s after contrast media administration. If needed, an additional urographic phase T1-weighted 3D gradient-echo LAVA sequence may be obtained in the sagittal, coronal and axial planes approximately 10 min after contrast administration. T2-weighted FRFSE, T2* and DW sequences are acquired with free-breathing technique, whereas T1-weighted 3D gradient-echo LAVA sequences are acquired in breath hold. T2* represents an optional sequence, not routinely performed

From: Cross-sectional imaging of acute gynaecologic disorders: CT and MRI findings with differential diagnosis—part I: corpus luteum and haemorrhagic ovarian cysts, genital causes of haemoperitoneum and adnexal torsion

MRI protocol Axial T2W SSFSE Sagittal T2W FRFSE Oblique-coronal/axial T2W FRFSE Axial T1W GRE in-out (chemical shift) Axial T2* Axial DWI SE EPI Sagittal, oblique-coronal/axial T1W 3D GRE LAVA
Repetition time/echo time (ms) 765/59 4675/100 4675/100 180/2.1 650/11.8 3000/74.1 4.4/2.1
Flip angle 90° 90° 90° 80° 20° 90° 12°
Section thickness (mm) 6 4 4 6 5 5 3.4
Interslice gap (mm) 0.6 0.4 0.4 0.6 0 1 −1.7
Bandwidth (kHz) 31.25 41.67 41.67 62.5 8.33 250 62.5
Field of view (cm) 38 32 32 38 25 46 40
Matrix 320 × 288 320 × 224 320 × 224 256 × 224 256 × 256 160 × 160 320 × 192
No. of averages 0.54 4 4 1 1 16 0.75
No. of images 30 26 26 20 30 28 104
Frequency direction Right to left Anterior to posterior Right to left   Anterior to posterior Anterior to posterior Superior to inferior
Acquisition time 24 s 3 min 49 s 3 min 49 s 22 s 1 min 28 s 3 min 18 s 22 s
b value (s/mm2) 0–800
  1. T2W T2-weighted, T1W T1-weighted, SSFSE single-shot fast spin-echo, FRFSE fast recovery fast spin-echo, DWI diffusion-weighted imaging, SE spin-echo, EPI echoplanar imaging, GRE gradient-echo, LAVA liver acquisition with volume acceleration