Skip to main content

Table 1 Clinical computed tomography (CT) and magnetic resonance imaging (MRI) protocols used in the current review

From: Tracking the glossopharyngeal nerve pathway through anatomical references in cross-sectional imaging techniques: a pictorial review

CT protocol

Acquisition

Detector coverage

Pitch

Table speed

Rotation time

Kv

mA max

ASIR

Matrix

FOV

Skull base

Spiral

20 cm

0.531:1

10.62 cm/s

1 s

120

600

40%

512

25 cm

Cranial

Spiral

20 cm

0.531:1

10.62 cm/s

0.8 s

120

280

40%

512

25 cm

Neck

Spiral

20 cm

0.531:1

10.62 cm/s

0.8 s

120

280

40%

512

25 cm

MRI protocol

Sequence

TR

TE

TI

ET

BW

Matrix

FOV

ST

SP

NEX

Brain

T2W axial

5600 ms

100 ms

22

41.67 KHz

512 × 384

26 cm

5 mm

1 mm

2

T2W coronal

4400 ms

102 ms

22

50 KHz

256 × 256

24 cm

5 mm

1 mm

2

T2W coronal

2800 ms

102 ms

22

41.67 KHz

320 × 256

24 cm

3 mm

0 mm

2

Cervical

T1W sagittal

3000 ms

22 ms

Auto

9

41.67 MHz

384 × 224

26 cm

3 mm

0 mm

2

Neck

T1W axial

475 ms

10 ms

3

20.83 KHz

256 × 256

18 cm

4 mm

1 mm

2

T2W axial

4200 ms

85 ms

13

15.63 MHz

256 × 256

18 cm

4 mm

1 mm

3

T1W coronal

350 ms

7 ms

3

31.25 MHz

256 × 192

18 cm

4 mm

1 mm

1