Skip to main content

Table 2 Pulmonary MR angiography protocol used at our institution on a 1.5-T magnet

From: Looking beyond the thrombus: essentials of pulmonary artery imaging on CT

 

Sequence type

Orientation

Slice thickness/gap (mm)

TE/TR (msec)

Flip angle (degrees)

Matrix

Field of view (mm)

Bandwidth (Khz)

NEX

Information acquired

Non-contrast

SSFP

Axial, coronal, ventricle short axis

4/0

1.4/3.4

45

200 × 160

350–420

125

0.75

Morphology, ventricle function

T1

Axial, short axis

6/0

42

90

256

38

62.5

1

Morphology, characterise mass lesions, oedema

T2

Axial, short axis

6/0

41/1,791

90

256 × 256

350

62.5

1

 

Phase Contrast

Perpendicular to pulmonary flow

8

2.7/5.6

25

192 × 128

350

31.25

1

Quantify pulmonary flow volume, peak-mean velocity, regurgitation

Contrast-enhanced MR angiography

MR angiography

Coronal

2.0

1.4/3.9

30

224 × 224

320–420

62.5

.5

Luminal assessment

Time resolved

Coronal

2.6

1.2/3.2

38

256 × 192

40

62.5

0.5–0.75

 

3D GRE

Axial

4/–2

1.9/3.9

12

320 × 160

320–420

83.3

0.75

 

Delayed enhanced

Axial, short axis

8/0

1.3/5.3

20

224 × 192

35

22.7

1

Thrombus, vessel wall, inflammation/scar