Skip to main content

Table 2 Summary of subjective image quality analysis of 2-mm, 5-mm and 5-mm MIP LD-CT data sets

From: Non-contrast CT at comparable dose to an abdominal radiograph in patients with acute renal colic; impact of iterative reconstruction on image quality and diagnostic performance

 

FBP m(SD)

P-value

ASIR-40 m(SD)

P-value

ASIR-70 m(SD)

P-value

ASIR-90 m(SD)

P-value

Diagnostic acceptability

2 mm

3(2)

0.000a

4(2)

0.000a

5(2)

0.000a

5(2)

0.000a

5 mm

4(2)

0.000b

5(2)

0.000b

6(2)

0.000b

5(2)

0.000b

5 mm MIP

2(1)

0.001c

3(1)

0.002c

4(1)

0.026c

4(2)

0.143c

Subjective noise

2 mm

9(1)

0.000a

8(0)

0.000a

7(0)

0.000a

6(0)

0.000a

5 mm

8(0)

0.000b

7(0)

0.000b

6(1)

0.000b

5(1)

0.000b

5 mm MIP

9(1)

0.026c

8(1)

0.022c

7(1)

0.016c

6(1)

0.012c

Spatial resolution

2 mm

4(1)

0.000a

4(1)

0.000a

5(2)

0.000a

5(2)

0.000a

5 mm

4(1)

0.000b

5(1)

0.000b

6(1)

0.000b

5(1)

0.000b

5 mm MIP

3(1)

0.015c

4(1)

0.075c

5(1)

0.068c

5(1)

0.693c

Contrast resolution

2 mm

3(1)

0.000a

4(2)

0.000a

4(2)

0.000a

5(2)

0.000a

5 mm

4(1)

0.000b

5(1)

0.000b

6(2)

0.000b

6(2)

0.000b

5 mm MIP

2(1)

0.001c

3(1)

0.007c

4(1)

0.088c

5(1)

0.144c