Table 5 Performance comparison of radiologists and ensemble model

From: Machine learning combined with radiomics and deep learning features extracted from CT images: a novel AI model to distinguish benign from malignant ovarian tumors

 

Without AI

With AI

Ensemble model

Junior radiologists averaged

Accuracy

0.66

0.81

0.82

Sensitivity

0.67

0.82

0.68

Specificity

0.65

0.80

0.89

Senior radiologists averaged

Accuracy

0.83

0.85

0.82

Sensitivity

0.82

0.82

0.68

Specificity

0.83

0.87

0.89