Skip to main content

Table 2 Comparison of ULD-CT and SD-CT protocols

From: Diagnostic accuracy of ultra-low-dose CT compared to standard-dose CT for identification of non-displaced fractures of the shoulder, knee, ankle, and wrist

Group

Shoulder (n = 24)

Knee (n = 17)

Ankle (n = 25)

Wrist (n = 26)

CTDI

(mGy)

DLP

(mGy × cm)

ED

(μSv)

CTDI

(mGy)

DLP

(mGy × cm)

ED

(μSv)

CTDI

(mGy)

DLP

(mGy × cm)

ED

(μSv)

CTDI

(mGy)

DLP

(mGy × cm)

ED

(μSv)

SD

14.78 ± 0.65

222.43 ± 30.54

2513.49 ± 345.13

11.46 ± 0.74

177.62 ± 21.43

71.05 ± 8.57

11.29 ± 0.39

173.01 ± 18.26

34.60 ± 3.65

4.43 ± 0.36

47.01 ± 11.30

9.40 ± 2.26

ULD

1.66 ± 0.06

25.51 ± 2.47

23.21 ± 2.24

0.34 ± 0.05

5.25 ± 0.61

2.10 ± 0.25

0.34 ± 0.05

5.82 ± 0.54

1.02 ± 0.11

0.10 ± 0.00

1.47 ± 0.32

0.29 ± 0.06

F

9827.75

991.24

1249.48

3833.18

1098.36

1098.36

19,564.92

2112.25

2112.25

3837.55

422.21

422.21

P

 < 0.0001

 < 0.0001

 < 0.0001

 < 0.0001

 < 0.0001

 < 0.0001

 < 0.0001

 < 0.0001

 < 0.0001

 < 0.0001

 < 0.0001

 < 0.0001