Skip to main content

Table 2 Visible length of the coronary artery of CCTA and NCMRA

From: 3D whole-heart noncontrast coronary MR angiography based on compressed SENSE technology: a comparative study of conventional SENSE sequence and coronary computed tomography angiography

 

Visible length of CCTA (mm)

SENSE

CS4

CS5

CS6

Visible length (mm)

R2

Visible length (mm)

R2

Visible length (mm)

R2

Visible length (mm)

R2

RCA

144 [127.625–163.8]

139.35 [121.9–166.9]

0.908

143.9 [122.15–161.875]

0.9339

142.85 [118.625–159.875]

0.9054

139.3 [114.625–157.775]

0.7163

LAD

92.3 [81.175–112.85]

88.95 [74.9–115.375]

0.7306

88.35 [77.15–114.15]

0.7485

88.35 [71.65–110.4]

0.6678

91.4 [72.15–105.9]

0.3895

LCX

77.5 [60.8–89.3]

75.85 [57.675–90.275]

0.9748

73.15 [60.075–87.25]

0.967

70.35 [58.9–83.9]

0.879

64.4 [54.4–83.375]

0.7828

  1. Metric data are reported as median and interquartile range