Skip to main content

Table 5 The results of fibrosis score between the selected population using both fibroscan and SWE technique with the fibroscan results used as the reference

From: 2D shear wave elastography (SWE) performance versus vibration-controlled transient elastography (VCTE/fibroscan) in the assessment of liver stiffness in chronic hepatitis

 

Fibroscan (VCTE) fibrosis score

Total

F0

F1

F2

F3

F4

SWE fibrosis score

F0

Count

34

0

0

0

0

34 (18.9%)

F1

Count

1

27

0

0

0

28 (15.6%)

F2

Count

1

3

23

2

0

29 (16.1%)

F3

Count

0

0

5

25

1

31 (17.2%)

F4

Count

0

0

2

9

47

58 (32.2%)

Total

Count

36

30

30

36

48

180

%

20%

16.7%

16.7%

20%

26.7%

100.0%

Chi-square tests

 

Value

P

Pearson chi-square

514.551

0.000