Skip to main content

Table 4 Diagnostic performance of CAD-RADS for patient-based detection of significant CAD

From: The validity and applicability of CAD-RADS in the management of patients with coronary artery disease

 

Reviewer 1

Reviewer 2

Reviewer 3

Reviewer 4

%

95% CI

%

95% CI

%

95% CI

%

95% CI

Accuracy

99.3

 

98.26

 

98.61

 

98.26

 

Sensitivity

100.00

97.22 to 100.00

100.00

97.22 to 100.00

100.00

97.22 to 100.00

100.00

97.22 to 100.00

Specificity

98.72

95.45 to 99.84

96.79

92.68 to 98.95

97.44

93.57 to 99.30

97.44

93.57 to 99.30

AUC

0.99

0.98 to 1.00

0.98

0.96 to 1.00

0.99

0.97 to 1.00

0.99

0.97 to 1.00

Disease prevalence

45.64

39.78 to 51.60

45.64

39.78 to 51.60

45.64

39.78 to 51.60

45.64

39.78 to 51.60

Positive predictive value

98.50

94.67 to 99.82

96.32

91.63 to 98.80

97.04

92.59 to 99.19

97.04

92.59 to 99.19

Negative predictive value

100.00

97.63 to 100.00

100.00

97.59 to 100.00

100.00

97.60 to 100.00

100.00

97.60 to 100.00

  1. AUC Area under curve, CAD coronary artery disease, CAD-RADS coronary artery disease reporting and data system, CI confidence interval