From: Dynamic magnetic resonance imaging of the female pelvic floor—a pictorial review
Pulse sequence | Imaging plane | TR/TE (msec) | FOV (cm) | Section thickness (mm) | Matrix | Study phase |
---|---|---|---|---|---|---|
T1-weighted localizer | – | – | Large | – | – | Rest |
T2-weighted turbo spin-echo | Axial | 6220/100 | 220 | 4 | 288/320 | Rest |
T2-weighted turbo spin-echo | Sagittal | 4000/100 | 220 | 4 | 202/320 | Rest |
T2-weighted turbo spin-echo | Coronal | 4860/100 | 240 | 4 | 288/320 | Rest |
TrueFISP | Midline Sagittal | 4.3/1.85 | 300 | 10 | 320/320 | Rest |
TrueFISP | Midline Sagittal | 4.3/1.85 | 300 | 10 | 320/320 | Squeezing |
TrueFISP | Midline Sagittal | 4.3/1.85 | 300 | 10 | 320/320 | Straining/Valsalva |
TrueFISP | Midline Sagittal | 4.3/1.85 | 300 | 10 | 320/320 | Defecation |