Skip to main content

Table 1 Study characteristics and MRI technical details

From: The role of MRI in axillary lymph node imaging in breast cancer patients: a systematic review

Technical MRI details

Author

Year

Study design

Field strength

Dedicated vs. covering*

Coil

Imaging sequences

Contrast used

Voxel size

Image analysis

Yoshimura et al.

1999

P

1.5 T

Dedicated

3-Inch circular SC

T1w

None

1.3 × 0.6 × 3.0 mm3

Short and long axis ratio and morphology

Kvistad et al.

2000

P

1.5 T

Dedicated

BC and extension to axilla

T1w, dynamic T1w

Gadodiamide

2.0 × 1.0 × 4.0 mm3

Normal diameter 2–3 mm, signal intensity time curves, morphology

Michel et al.

2002

P

1.5 T

Dedicated

Cardiac SC

T1w, T2w, T2*w

Ferumoxtran-10

T1w 0.9 × 0.9 × 3.5, T2w 0.4 × 0.4 × 3.5, T2*w 0.9 × 0.9 × 2.0 mm3

Size, shape, long-shirt axis ratio, USPIO uptake patterns

Harada et al.

2007

P

1.5 T

Dedicated

Cardiac surface coil

T1w, T2*w, dynamic T2*w

Ferumoxtran-10

0.63 × 1.25 × 0.5 mm3

Pre contrast: short axis >5 or >10 mm, replacement fatty hilum, irregular margins. USPIO: heterogeneous uptake or lack of uptake

Orguc et al.

2012

P

1.5 T

Breast and axilla

Not reported

T2w, dynamic T1w

Not reported

Not reported

Size, SI time curves

Fornasa et al.

2012

P

1.5 T

Breast and axilla

4-Channel phased array coil

T1w, T2w, dynamic T1w, DWI (b-value 0/800)

Gadoterate meglumine

T2w 1.3 × 1.3 × 4.0; T1w 1.1 × 1.3 × 4.0; dynamic T1w 1.4 × 1.4 × 1.8; DWI 5.3 × 5.3 × 4.0 mm3

Lymph node area, ADC

He et al.

2012

P

1.5 T

Breast and axilla

8-Channel BC

T1w, dynamic T1w, T2w, DWI (b-value 0/500/800)

Gadopente-tate dimeglumine

Dynamic T1w 1.1 × 1.1 × 2 mm3; DWI 2.7 × 2.7 × 4 mm3; T1w not reported (only ST: 5 mm)

SI time curve, shape, margin, diameter, long/short axis ratio, node anatomical location, ADC values, high SI on DWI, early stage enhancement

Scaranelo et al.

2012

P

1.5 T

Breast and axilla

8-Channel BC

T1w, T2w, DWI (b-value 0/50/300/700/1000)

None

T1 0.7 × 0.9 × 1.2 mm3; (T2 not reported; DWI only ST: 4 mm)

Shape, presence of fatty hilum, cortex irregular, lobulated margins, visual inspection of DWI and ADC

Hwang et al.

2013

R

1.5 T

Breast and axilla

4-Channel BC

T1w, T2w, DWI (b-value 750/1000), Dynamic T1w

Gadopente-tate dimeglumine

Not reported (only ST: T1w 3.4, T2w 2.6, DWI 3.4, Dynamic T1w 2.6 mm)

Cortical thickening, irregular or round shape, loss of fatty hilum

Luo et al.

2013

P

1.5 T

Breast and axilla

8-Channel BC

T1w, T2w, DWI

None

T1w 1.0 × 0.7 × 1.0; T2w 1.1 × 1.1 × 4.03; DWI 1.0 × 0.7 × 6.0 mm3

Lymph nodes >4 mm, ADC values

Kamitani et al.

2013

R

1.5 T

Breast and axilla

Body coil

T1w, dynamic T1w, T2w, DWI

   

(b-Value 0/1000)

Gadopente-tate dimeglumine

T1w 0.93 × 0.93 × 4.0 mm3; DWI 2.8 × 4.1 × 5.0 mm3 (T2w not reported)

Short axis, detectability on DWI

      

Basara et al.

2013

P

1.5 T

Breast and axilla

8-Channel BC

CE-T1w, T2w, DWI

   

(b-Value 0/600)

Not reported

DWI: 0.2 × 0.2 × 5.0 mm3; other sequences not reported

Size, ADC

      

Hieken et al.

2013

R

1.5 T

Breast and axilla

BC

Dynamic T1w

Gadobenate dimeglumine

Not reported

Cortical thickness >3 mm, asymmetric cortex, shape, unclear margins, perinodular oedema, loss or displacement of hilum, matting

Abe et al.

2013

P

1.5 T

Breast and axilla

BC

T2w, dynamic T1w

Gadodiamide

1.0 × 1.0 mm2, ST not reported

Diffuse and asymmetrical cortical thickening, loss of hilum

Li et al.

2014

P

3.0 T

Dedicated

12-Channel body coil

T1w, T2w, T2*w

None

0.8 × 0.8 × 3.0 mm3

T2* values

An et al.

2014

R

1.5 or 3.0 T

Breast and axilla

BC

T2w, T1w, dynamic T1w

Gadobutrol

Both 1.5T and 3.0T; T2w ST 3 mm, dynamic unenhanced and CE T1w FOV 320 × 320, ST 3 mm

Loss of fatty hilum, cortex thickness of >3 mm, irregular or round shape on T2w