Skip to main content

Table 2 Normal values of myocardial ECV at different studies

From: T1 mapping: characterisation of myocardial interstitial space

  Field strength Scanner Contrast Technique Dose (mmol/kg) T1 mapping sequence ECV (%)
Broberg et al. [60] 2010 1.5 T/3 T Achieva/Intera, Philips Gadodiamida Only bolus 0.15 Look-Locker 24.8
Schelbert et al. [56] 2011 1.5 T Espree, Siemens Gadoteridol Only bolus 0.2 MOLLI 24.1
Lee et al. [58] 2011 3 T Verio, Siemens Gadopentetate Dimeglumine Only bolus 0.15 MOLLI 26.7
Kellman et al. [61] 2012 1.5 T Avanto/Espree, Siemens Gd-DTPA Only bolus 0.15 MOLLI 25.4
Sado et al. [85] 2012 1.5 T Avanto, Siemens Gadoterate Meglumine Bolus + infusion 0.1 + 0.002/mina FLASH IR 25.3
Salerno et al. [62] 2013 1.5 T Avanto, Siemens Gd-DTPA Bolus + infusion 0.1 + 0.001/minb MOLLI 28.5
Liu et al. [86] 2013 1.5 T Avanto/Espree, Siemens Gadopentetate Dimeglumine Only bolus 0.15 MOLLI 26.9
  1. aBolus of 0.1 mmol/kg followed by infusion of 0.002 mmol/kg/min
  2. bBolus of 0.1 mmol/kg followed by infusion of 0.001 mmol/kg/min