From: T1 mapping: characterisation of myocardial interstitial space
Field strength | Scanner | Reception coil | T1 mapping sequence | T1 values (ms) | |
---|---|---|---|---|---|
Messroghli et al. [42] 2006 | 1.5 T | Gyroscan Intera CV, Philips | – | MOLLI | 980 ± 53 |
Piechnik et al. [36] 2010 | 1.5 T | Avanto, Siemens | 32-channel | ShMOLLI | 966 ± 48 |
1.5 T | Avanto, Siemens | 32-channel | MOLLI | 976 ± 46 | |
3 T | Trio, Siemens | 16-channel | ShMOLLI | 1,166 ± 60 | |
3 T | Trio, Siemens | 16-channel | MOLLI | 1,169 ± 45 | |
Lee et al. [58] 2011 | 3 T | Verio, Siemens | 32-channel | MOLLI | 1,315 ± 39 |
Rogers et al. [59] 2013 | 1.5 T | Philips, Best | 32-channel | MOLLI | 976 ± 37 |
3 T | Philips, Best | 32-channel | MOLLI | 1,108 ± 67 | |
Von Knobelsdorff et al. [49] 2013 | 3 T | Verio, Siemens | 32-channel | MOLLI | 1,158 (range, 1,005–1,295) |
Kellman et al. [82] 2013 | 1.5 T | Avanto, Siemens | 32-channel | MOLLI | 1,012 ± 25 |
Piechnik et al. [83] 2013 | 1.5 T | Avanto, Siemens | 16-channel | ShMOLLI | 962 ± 25 |
1.5 T | Avanto, Siemens | 32-channel | ShMOLLI | 962 ± 25 | |
Puntmann et al. [74] 2013 | 3 T | Achieva TX, Philips | 32-channel | MOLLI | 1,070 ± 55 |
Fontana et al. [76] 2014 | 1.5 T | Avanto, Siemens | 16-channel | ShMOLLI | 967 ± 34 |
Liu et al. [84] 2014 | 3 T | Trio, Siemens | 12-channel | MOLLI | 1,232 ± 51 |